What is the solution for the integrated stove not igniting? Is the integrated stove plugged in or battery charged?

What is the solution for the integrated stove not igniting? Is the integrated stove plugged in or battery charged?

Integrated stoves are household appliances that are highly chosen by people for home decoration and kitchen appliances. The more functions they have, the more convenient they are to use, but the greater the probability of various small problems arising. Today, let’s talk about the small problems that are often encountered when using integrated stoves, hoping to bring convenience to everyone in solving them.

Contents of this article

1. What is the solution for the integrated stove not igniting?

2. Why can’t the integrated stove boil water?

3. Is the integrated stove plugged in or battery-charged?

4. What should I do if the integrated stove has no electricity?

1

What is the solution for the integrated stove not igniting?

1. There is no gas. If the bottled gas is out of gas, you need to add gas; if it is pipeline gas, make sure the gas valve switch is open.

2. The battery is out of power. If the integrated stove battery is out of power or used up, just replace it with an ordinary D-type battery.

3. Poor circuit contact. If the integrated stove circuit has poor contact, you need to remove the rust and connect the circuit accurately.

4. Overpressure protection: If the integrated stove has overpressure protection, you should try replacing the pressure reducing valve.

5. Pipeline blockage. If the integrated stove pipeline is blocked, you need to dredge the pipeline or replace it.

6. The micro switch is damaged. The micro switch of the integrated stove is damaged. This is a delicate and professional job, so it is best to ask a professional to solve it.

7. The ignition needle is dirty. At this time, you need to clean the grease on the ignition needle and then try to ignite it.

8. The ignition needle is not in the right position. Generally speaking, the distance between the ignition needle and the fire cover is 4-6mm, and it should be aligned with the fire hole.

2

Why can't the integrated stove boil water?

1. The angle valve opening is too small. In this case, you can open a larger angle valve.

2. For integrated stoves that use pipe burners, the flame may be very small due to the small diameter of the pipe and rust and blockage inside the pipe.

3. When the hose is flattened or bent, the air volume is small. If the air flow is blocked when the hose is bent, the hose can be straightened. If the hose is flattened, it can be replaced with a new one.

4. The nozzle of the pressure reducing valve or the nozzle of the gas stove is clogged. When the nozzle of the pressure reducing valve or the integrated stove is clogged, the gas will not be ejected smoothly and the burning flame will be weak. The solution is to clear the nozzle with a thin steel wire.

3

Is the integrated stove plugged in or battery charged?

It is usually plugged in because changing the battery is very troublesome.

Integrated stoves, also known as environmentally friendly stoves or integrated environmentally friendly stoves in the industry, are kitchen appliances that integrate multiple functions such as range hoods, gas stoves, disinfection cabinets, and storage cabinets. They have the advantages of saving space, good fume extraction, energy saving, low consumption, and environmental protection. The general integrated stove has an oil absorption rate of 95%. The higher the oil fume absorption rate, the better the quality. Some brands of integrated stoves have an oil fume absorption rate of 99 or 95%.

4

What should I do if the integrated stove has no electricity?

The integrated stove has no power, first of all, you should check whether you have installed batteries. If not, try to install the batteries first. If there is no response, then there is a problem with the stove circuit, and you need to contact after-sales service and a professional repairman for inspection. If it can ignite after installation, it means that there is a problem with the AC circuit and the rectifier circuit of the stove itself. You need to check the integrated stove plug, socket, and whether the leakage switch of the electrical box is tripped. If there is no problem, you will eventually ask the master to repair it.

<<:  What is an integrated stove? What are the selection tips for integrated stoves?

>>:  What are the benefits of practicing Ba Duan Jin? Who is Ba Duan Jin not suitable for?

Recommend

How many times a year should I take emergency contraceptive pills?

Many friends fail to take timely contraceptive me...

Tubal ligation surgery costs

For female friends, sterilization surgery is not ...

Pregnancy ultrasound single picture

It is very important for every pregnant mother to...

What should women eat to nourish yin and kidney

There is a wrong perception in the minds of many ...

What is the cause of vaginal bleeding?

Normal vaginal bleeding in women is a manifestati...

Non-surgical facial wrinkle removal

From ancient times to the present, women have wan...

What does it mean when a girl's lips turn pale?

Girls are particularly concerned about their imag...

What are the symptoms of polycystic ovarian syndrome?

Polycystic ovary syndrome is a common disease amo...

What causes breast swelling in women?

Women's breasts are more fragile than men'...

Is progesterone 27 normal?

In early pregnancy, progesterone levels are very ...

Is there any way to urge my aunt to come?

Most methods to induce menstruation require takin...

Female thigh muscle pain

Thigh pain can occur in several locations, includ...